Marshall Stability Test Apparatus

Originally developed by Bruce Marshall, a higher engineer in U.S.A. later on standardized by ASTM. Generally the test is applicable to hot mix designs using bitumen and aggregates up to a maximum size of 25mm. In this method, the resistance to plastic deformation of cylindrical specimen of bitumenous mixture is measured when the same is loaded at periphery at 5 cm per min. This test procedure is used in designing and evaluating bitumenous paving mixes. The test procedure is extensively used in routine test programmes for paving jobs. There are two major features of the marshal method of designing mixes namely
a) Density - Voids analysis
b) Stability- Flow Tests

The marshal stability of mix is defined as a maximum load carried by a compacted specimen at a standard test temperature of 60 degree celsius. The flow value is deformation. the marshal test specimen undergoes during the loading up to the maximum load, in 0.25 mm units. In this test an attempt is made to determine optimum binder content for the type of aggregate mix and traffic intensity. The apparatus consists of :
1) A loading unit motorized, capacity 5000 Kgf with two telescopic pillars and an adjustable cross head. Limits switches are fitted inside to control upward or downward movements of the pillars. On/Off reversing switch and indicators lamps are on the front side while a hand wheel to manually move the pillars is on the right. The load frame has fixed speed of 5.08 cm/minute. Operated on 230 Volts A.C.
2) One number compaction pedal with specimen mould holder.
3) Two Nos. Compaction Rammers, 4.5 Kg weight and free fall 45.7 cm.
4) One nos. breaking head assembly with provision to fix flowmeter.
5) 3 nos. specimen mould 10.16 cm I.D. * 7.6cm high with base plate and extension collar
6) 1 Nos. kit for specimen extraction consist of one each load transfer bar, steel bar , pecimen extracting plate.
Accessories: a) Integral type proving ring cap. 3000 kgs
b) A Dial gauge 0.01 * 25 mm
c) Universal water bath S.S. with false bottom and pyramid shaped lid to accomodates 3 nos marshal specimen
d) Thermometer 0-250 degree celsius *1 degree celsius.

 